Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)

  P0614 00


Control module not added.

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Wrong variant programmed in control module.

Dependent:

None

System reaction to a fault:

None

OK report:

Fault criteria NOT fulfilled.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Diagnostic help

Diagnosis regards:

See "After fitting a control module" under fault diagnosis, general.
Add control module using diagnostic tool or carry out SPS programming.

Functions in the diagnostic tool related to the fault: