ME9 / P0616 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: The starter motor may function independently.
Starter Relay Circuit, Short to Ground
Fault symptom
The starter motor may function independently.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage must be between 10 - 18 V. |
Fault criteria:
When output voltage is close to 0 for more than 1 second. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |