ME9 / P2229 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Malfunction Indicator Lamp
Atmosphere Pressure Sensor Circuit, Short to B+
Fault symptom
Malfunction Indicator Lamp
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage must be between 10 - 18 V. |
Fault criteria:
When input voltage exceeds 4.65 V for more than 0.5 seconds. |
When the sensor indicates a pressure of 12 kPa for more than 2 seconds. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |