ME9 / P2270 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Malfunction Indicator Lamp
O2S 2 Signal, Stuck Lean
Fault symptom
Malfunction Indicator Lamp
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage greater than 10.5 V. |
Preheating circuit in normal operating range for more than 20 seconds. |
Calculated exhaust temperature between 250°C and 800°C. |
Air mass more than 10 g/s. |
Fault criteria:
An extra test is inititated if the O2S 2 signal is less than 650 mV for more than 100. The control module enriches the system with 30% extra fuel. A diagnostic code is generated if the signal does not change after 10 seconds under these conditions. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Improperly mounted/defective sensor |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |