Read the instructions below then start the fault diagnostic procedure.

Symptom: Malfunction Indicator Lamp

  P2626 00


O2S 1 Pumping Current Trim Circuit, Open

Fault symptom

Malfunction Indicator Lamp

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage should be between 10.7 and 16 Volts.
Engine running.
Sensor in normal operating range (715°C and up).
Fuel Cut

Fault criteria:

Trim circuit voltage is over 4.8 V for 2 seconds or 600 seconds if fuel level is less than 12%.
Open circuit on the lead between control module pin A35 and sensor pin 5.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Requested O2S1 Lambda
O2S1 lambda
O2S1 Pump Current
O2S 1 Preheating
Short Term Fuel Trim Status
Closed Loop
Total Fuel Trim