SAAB WIS ONLINE

PDM / B1600 02

Read the instructions below then start the fault diagnostic procedure.

Symptom: Power mirror cannot be operated

  B1600 02


Mirror Motor Common Circuit, Short to Ground

Fault symptom

Power mirror cannot be operated

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
During electric mirror operation.
NONE of the following DTCs must be detected:
B1723
B1724

Fault criteria:

Control module input short circuit to ground.

System reaction to a fault:

The motor attempts to activate the electric mirror left/right function four times during each new driving cycle.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Mirror Motor Passenger Door
(See also description of readings/activations in diagnostic tool)