SAAB WIS ONLINE

PDM / B2652 02

Read the instructions below then start the fault diagnostic procedure.

Symptom: Button lighting lit continuously.

  B2652 02


Switch Illumination Circuit, Open

Fault symptom

Button lighting lit continuously.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

When panel lighting is activated.

Fault criteria:

Control module signal invalid.

System reaction to a fault:

The control module attempts to activate button lighting during each new driving cycle.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Switch Illumination Passenger Door
(See also description of readings/activations in diagnostic tool)