PSM / B1765 04
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Memory functions not working
Height Motor Output Circuit, Open
Fault symptom
Memory functions not working
On-board diagnosis
Type of diagnosis:
Continually when the engine is run. |
Enable criteria:
When seat operation is permitted. |
Fault criteria:
Voltage on the control module output is below 6 ±0.2V. |
Voltage on the control module output is below B+ -0.7V. |
System reaction to a fault:
Output is switched off, tries however to activate the engine once each time the ignition is switched on. |
OK report:
Fault criteria NOT fulfilled. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |