SAAB WIS ONLINE

PSM / B1765 61

Read the instructions below then start the fault diagnostic procedure.

Symptom: Memory functions not working Output is switched off, tries however to activate the engine once each time the ignition is switched on.

  B1765 61


Height Motor Output Circuit, Relay Stuck to Ground

Fault symptom

Memory functions not working

Output is switched off, tries however to activate the engine once each time the ignition is switched on.

On-board diagnosis

Type of diagnosis:

Immediately after a soft start is completed.

Enable criteria:

When seat operation is permitted.

Fault criteria:

Voltage on the control module output is below 6 ±0.2V.

System reaction to a fault:

No memory functions work
Output is switched off, tries however to activate the engine once each time the ignition is switched on.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activate:
Motor, Height Up
(See also description of readings/activations in diagnostic tool)