REC / B2545 02
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Left-hand reversing light, faulty function.
Message appears in display.
Back Up Light Left Circuit, Short to Ground
Fault symptom
Left-hand reversing light, faulty function.
Message appears in display.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Left-hand reversing light on. |
Fault criteria:
Current consumption greater than 6 A for more than 6 ms |
System reaction to a fault:
Control module output is switched off. |
Checking the wiring harness
The control module's output also supplies power to the control module ADM
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault: