SAAB WIS ONLINE

REC / B2545 02

Read the instructions below then start the fault diagnostic procedure.

Symptom: Left-hand reversing light, faulty function. Message appears in display.

  B2545 02


Back Up Light Left Circuit, Short to Ground

Fault symptom

Left-hand reversing light, faulty function.

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Left-hand reversing light on.

Fault criteria:

Current consumption greater than 6 A for more than 6 ms

System reaction to a fault:

Control module output is switched off.

Checking the wiring harness

The control module's output also supplies power to the control module ADM

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation:
Back Up Light Left