Symptom: Electrical seat operation always possible or electrical seat operation not working.
Power Seat Enable Relay Circuit, Open/Short to Ground
Fault symptom
Electrical seat operation always possible or electrical seat operation not working.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Diagnostics run when electrical seat operation is not permitted. |
Fault criteria:
Output voltage is below 6 V. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |