SLM / P1801 06
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Selector lever locked in position P or N.
Shift lock-solenoid, Open/Short to Ground.
Fault symptom
Selector lever locked in position P or N.
On-board diagnosis
Type of diagnosis:
Enable criteria:
System reaction to a fault:
Control module closes output to Shift Lock solenoid. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault: