SPA / B1350 02
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Message appears in display.
SPA stops all measurements and the acoustic signals from SID for SPA are switched off.
Sensor Feed. Short to Ground.
Fault symptom
• | Message appears in display. |
• | SPA stops all measurements and the acoustic signals from SID for SPA are switched off. |
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
When voltage on output is below 7.2 V. |
System reaction to a fault:
Control module stops measurement and is set to standby mode. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Fault diagnosis refers to electrical faults in connected leads or the distance sensors. |
Functions in the diagnostic tool related to the fault: