STC / B3685 58
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Message appears in display.
The soft top stops somewhere in its cycle.
1st Bow Ready to Latch, Position Sensor, Wrong Response
Fault symptom
Message appears in display.
The soft top stops somewhere in its cycle.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Soft top opening/closing activated |
Fault criteria:
The position sensor assumes impermissible position while soft top is in operation |
Diagnostic help
• | The distance between the sensor and the sensor detection point must not exceed 1.9 mm. |
• | The soft top is operated in sequences. Each sequence must begin with the sensors in a position that matches the movement pattern. |
Diagnostic help
Functions in the diagnostic tool related to the fault: