STC / B3685 59
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Message appears in display.
The soft top stops somewhere in its cycle.
1st Bow Ready to Latch, Position Sensor, Timeout
Fault symptom
Message appears in display.
The soft top stops somewhere in its cycle.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Soft top opening/closing activated |
Fault criteria:
Too long before position sensor changes status |
Diagnostic help
Diagnosis regards:
Check that the bow is locked within the specified time |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |