T8 / P0132 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)

  P0132 00


O2S Circuit. High Voltage. Sensor 1.

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 11 - 16 V.
Engine running.
Preheating active for more than 4 s.

Fault criteria:

When voltage across the sensor is more than 1200 mV for 5 s.

Dependent:

None

System reaction to a fault:

Closed loop is blocked.
Preheating of oxygen sensors 1 and 2 is stopped.
Fuel adaptation is reset and switched off.

OK report:

Fault criteria NOT fulfilled for 6 s.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
O2S 1
Closed Loop

(See also description of readings/activations in diagnostic tool)