T8 / P0246 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Limp home
Charge Air Control Valve Circuit. Short to B+.
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Limp home
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
When voltage on the output exceeds 2.0 V for more than 1 s. |
Dependent:
System reaction to a fault:
Torque limited to max. 170Nm. |
OK report:
When the fault criterion is NOT fulfilled for 2 s and the PWM signal on the output exceeds 3%. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
• | Charge Air Control Valve |
(See also description of readings/activations in diagnostic tool) |