T8 / P0445 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
EVAP Purge Valve Circuit. Short to B+.
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage must be between 11 - 16 V. |
NONE of the following DTCs must be detected: |
Fault criteria:
Output voltage exceeds 2 V during the portion of the PWM period when the control module is grounding. The condition exists for more than 2 s. |
Dependent:
System reaction to a fault:
Fuel adaption is blocked and reset. |
EVAP canister purge valve deactivated. |
OK report:
Diagnostics carried out without fault reported. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |