T8 / P0499 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Canister Close Valve Circuit. Short to B+.
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage must be between 11 - 16 V. |
NONE of the following DTCs must be detected: |
Fault criteria:
When voltage on the output exceeds 2.0 V for more than 1 s. |
Dependent:
System reaction to a fault:
Fuel adaption is blocked and reset. |
OK report:
Fault criteria NOT fulfilled for 6 s. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |