SAAB WIS ONLINE

T8 / P0607 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Limp home

  P0607 00


Control Module. Internal Fault

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Limp home

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Control module on-board diagnostics has detected a fault in the processor which controls the throttle.

Dependent:

None

System reaction to a fault:

Limited acceleration and idle function.

OK report:

Fault criterion not fulfilled and vehicle speed over 0 km/h for more than 60 s.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Diagnostic help

Diagnosis regards:

To locate electrical faults in the control module internal electronics.
See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general.

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"