SAAB WIS ONLINE

T8 / P0686 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Engine does not start. Engine stops.

  P0686 00


Main Relay Coil Circuit. Open / Short to Ground.

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Engine does not start.

Engine stops.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Crankshaft rotating.
Output is not active.
Diagnosis is carried out when the engine is switched off with the ignition key.

Fault criteria:

When voltage on the output is below 2.0 V for more than 1 s.

Dependent:

None

System reaction to a fault:

None

OK report:

Fault criteria NOT fulfilled during 60 s with engine running.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation:
Main Relay

(See also description of readings/activations in diagnostic tool)