T8 / P1132 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
O2S. Switch point - rich. Sensor 1
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
On-board diagnosis
Type of diagnosis:
Enable criteria:
Engine speed between 1500 and 2800 rpm. |
Engine load between 200 - 400 mg/c. |
Closed loop is blocked (rich or lean) for a number of combustions in order to maintain 0.7V from oxygen sensor 2. The prescribed number of combustions is adapted. |
Fault criteria:
Closed loop blocked in lean mode for more than 50 combustions. |
Dependent:
System reaction to a fault:
OK report:
Diagnosis completed without fault report. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Diagnostic help
Diagnosis regards:
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |