SAAB WIS ONLINE

T8 / P1606 00

Read the instructions below then start the fault diagnostic procedure.

  P1606 00


Control Module. Internal Fault



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Control module on-board diagnostics has detected a fault in the main processor.

Dependent:

None

OK report:

Fault criterion not fulfilled and vehicle speed over 0 km/h for more than 60 s.

Fault handling:

Type III without Check Engine.
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Diagnostic help

Diagnosis regards:

To locate electrical faults in the control module internal electronics.
See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general.

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"