SAAB WIS ONLINE

T8 / P2126 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Limp home Message appears in display.

  P2126 00


Pedal Position Sensor 2 Circuit. Out of Range.

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Limp home

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

When the ECM is awake, diagnosis is active (even with the ignition off).

Fault criteria:

When input voltage is outside the range 0.13 - 2.5 V.

Dependent:

None

System reaction to a fault:

Limp home

OK report:

Fault criterion not fulfilled and vehicle speed over 0 km/h for more than 60 s.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Pedal Position Sensor 2

(See also description of readings/activations in diagnostic tool)