T8 / P2501 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Higher idling speed.
Generator L Terminal Control Circuit, Short to B+
Fault symptom
Higher idling speed.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
The lead between control module pin B16 and generator pin 1 (D+) is short-circuited to B+ for more than 1 s. |
Dependent:
System reaction to a fault:
Control module continues working with the higher idling function. |
OK report:
Fault criteria NOT fulfilled for 2 s. |
Fault handling:
Type III without Check Engine. |
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
• | Alternator L Terminal Load Dump |
(See also description of readings/activations in diagnostic tool) |