TCM ME9 / P0601 00
Read the instructions below then start the fault diagnostic procedure.
Symptom: Message appears in display. TCM in Limp Home.
P0601 00 |
Fault symptom
Message appears in display.TCM in Limp Home.
On-board diagnosis
Type of diagnosis:
Diagnostics run each time control module "wakes". |
Enable criteria:
Ignition ON. |
Fault criteria:
Control module on-board diagnostics has detected a ROM error. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.Diagnostic help
Diagnosis regards:
To locate electrical faults in the control module internal electronics. |
Functions in the diagnostic tool related to the fault:
See menu "All - Add/Remove" |
____________________________________ |
See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general. |