SAAB WIS ONLINE

TCS/ESP / C0895 08

Read the instructions below then start the fault diagnostic procedure.

Symptom: ESP warning lamp on. Message appears in display.

  C0895 08


Yaw Rate Sensor, Supply Voltage Out of Range

Fault symptom

ESP warning lamp on.

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Voltage to yaw rate sensor below 7.8 V for 10 seconds with ignition on.

System reaction to a fault:

No ESP function

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

The sensor is a combined yaw angle sensor and lateral acceleration sensor.