Symptom: Left-hand main beam, faulty function. Message appears in display.

  B2580 04


High Beam Left Circuit, Open

Fault symptom

Left-hand main beam, faulty function.

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Main beam on.

Fault criteria:

Current consumption is below 0.8 A.

System reaction to a fault:

None

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation:
High Beam Left