SAAB WIS ONLINE

UEC / B3868 02

Read the instructions below then start the fault diagnostic procedure.

Symptom: Front left side direction indicator malfunction. Message appears in display.

  B3868 02


Turn Indicator Repeater Right Front Circuit, Short to Ground

Fault symptom

Front left side direction indicator malfunction.

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Left direction indicators on.

Fault criteria:

Current consumption greater than 6 A for more than 6 ms

System reaction to a fault:

Control module output is switched off.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation:
Turn Indicator Repeater Left Front
(See also description of readings/activations in diagnostic tool)