MID
|
TID
|
Unit/scale
|
Fault Code supported
|
Data
|
Min value
|
Max value
|
O2 sensor, B1S1
|
$01
|
$83
|
05
|
|
Dynamic value calculated
|
0.300
|
1.999
|
O2 sensor, B1S2
|
$02
|
$01
|
0A
|
|
Minimum sensor voltage
|
0.601
|
0.601
|
|
$02
|
0A
|
|
Lean to rich threshold voltage
|
0.601
|
0.601
|
|
$07
|
0A
|
|
Minimum sensor voltage
|
0
|
0.450
|
|
$08
|
0A
|
|
Maximum sensor voltage
|
0.450
|
1.079
|
|
$81
|
0A
|
|
Minimum sensor voltage of oscillation check
|
0
|
0.601
|
|
$82
|
0A
|
|
Maximum sensor voltage of oscillation check
|
0.601
|
1.079
|
|
$83
|
0A
|
|
Offset voltage downstream pre catalyst
|
0
|
0.201
|
Catalyst monitor
|
$21
|
$81
|
01
|
P0420
|
Catalyst monitor, evaluated value
|
4096
|
65535
|
EVAP monitor, cap off
|
$39
|
$80
|
81
|
P0455
|
EVAP, monitor Cap off
|
-32768
|
-1770
|
EVAP monitor, 0,020"
|
$3C
|
$83
|
05
|
P0456
|
EVAP monitor leak factor.
|
0
|
0
|
EVAP monitor, 0,020"
|
$3C
|
$83
|
01
|
P0456
|
EVAP monitor leak factor.
|
0 to 65535 counts
|
1 count/bit
|
The same value is reported in MID:s 39 and 3C. When a large leak is present, all CID:s will show "Fail".
|
|
3D
|
$8C
|
81
|
|
Tank pressure after purge valve is closed.
|
-8602
|
32767
|
|
$88
|
81
|
|
Tank pressure to detect stucked purge valve.
|
-32768
|
-6
|
O2 sensor,heater monitor B1S1
|
41
|
$85
|
16
|
|
Heater power
|
714.9
|
1262.8
|
O2 sensor,heater monitor B1S2
|
42
|
$81
|
14
|
|
Resistance of ceramic
|
N/A
|
572
|
AIR monitor
|
$71
|
$80
|
05
|
|
SAI air flow value
|
0.750
|
1.999
|
Fuel System Monitor Bank 1
|
$81
|
$80
|
AF
|
|
Additive correction factor
|
-5.25
|
+5.25
|
|
$82
|
05
|
|
Multiplicative correction factor
|
0.825
|
1.174
|
Misfire Monitor
|
$A2
|
$0B
|
24
|
P0300/P0301
|
EWMA misfire counts, cylinder 1
|
0
|
65535
|
|
$0C
|
24
|
P0300/P0301
|
DCY misfire counts, cylinder 1
|
0
|
65535
|
$A3
|
$0B
|
24
|
P0300/P0302
|
EWMA misfire counts, cylinder 2
|
0
|
65535
|
|
$0C
|
24
|
P0300/P0302
|
DCY misfire counts, cylinder 2
|
0
|
65535
|
$A4
|
$0B
|
24
|
P0300/P0303
|
EWMA misfire counts, cylinder 3
|
0
|
65535
|
|
$0C
|
24
|
P0300/P0303
|
DCY misfire counts, cylinder 3
|
0
|
65535
|
$A5
|
$0B
|
24
|
P0300/P0304
|
EWMA misfire counts, cylinder 4
|
0
|
65535
|
|
$0C
|
24
|
P0300/P0304
|
DCY misfire counts, cylinder 4
|
0
|
65535
|
$A6
|
$0B
|
24
|
P0300/P0305
|
EWMA misfire counts, cylinder 5
|
0
|
65535
|
$A7
|
$0B
|
24
|
P0300/P0305
|
DCY misfire counts, cylinder 5
|
0
|
65535
|
|
$0B
|
24
|
P0300/P0306
|
EWMA misfire counts, cylinder 6
|
0
|
65535
|
|
$0C
|
24
|
P0300/P0306
|
DCY misfire counts,cylinder 6
|
0
|
65535
|