SAAB WIS ONLINE

EDC16 MY07½ / P0615 04

Read the instructions below then start the fault diagnostic procedure.

Symptom: Starter motor cannot be started.

  P0615 04


Starter Relay Actuator Circuit, Open

Fault symptom

Starter motor cannot be started.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

No voltage on the control module output for more than 0.6 s

System reaction to a fault:

None

OK report:

Fault criteria NOT fulfilled for 6.5 s.

Checking the wiring harness

Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force.
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:


Functions in the diagnostic tool related to the fault:

Test value:
Starter Relay
(See also description of readings/activations in diagnostic tool)