EDC16 MY07½ / P1625 57

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Engine shut off. Engine does not start.

  P1625 57


Main Relay Circuit. Voltage drops to late

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Engine shut off.

Engine does not start.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Engine running.

Fault criteria:

Time difference between control module grounding of the relay and discontinued control module power supply is more than 2 seconds.

Checking the wiring harness

Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force.
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:


Functions in the diagnostic tool related to the fault:

Test value:
Main Relay_dummy
Activation:
Main Relay_dummy
(See also description of readings/activations in diagnostic tool)