T8 / P1624 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Engine may not start.
CIM Missing on Bus
Fault symptom
Engine may not start.
On-board diagnosis
Type of diagnosis:
Enable criteria:
| Ignition on for at least 3 s. |
| Battery voltage must be between 6 - 18 V. |
Fault criteria:
| No communication with CIM for 1.25 s. |
Dependent:
System reaction to a fault:
| The control module uses substitute value +20°C for outside temperature. |
OK report:
| Fault criteria NOT fulfilled for 2 s. |
Fault handling:
| Type III without Check Engine. |
| (See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault on bus leads or in the component. |
| Fault diagnosis for CIM should be carried out. |
Functions in the diagnostic tool related to the fault:
| Response test, under "All/Bus" menu. |
| Read / Reset Bus Configuration |
| Read / Clear Bus Off Counter |