T8 / P2301 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Flickering pressure indicator in MIU.
Misfiring
Jerky movements.
Performance loss.
Ignition Coil Trig Cylinder 1 Circuit, Open/Short to B+

Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Flickering pressure indicator in MIU.
Misfiring
Jerky movements.
Performance loss.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
| Output voltage below 2 V when the control module is not grounding. |
| The condition exists for more than 1 s. |
Dependent:
System reaction to a fault:
| Fuel to the injector in question is cut off. |
| Fuel adaption is blocked and reset. |
OK report:
| Fault criteria NOT fulfilled for 2 s. |
Fault handling:
| (See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault in the ignition coil connecting leads. |
Functions in the diagnostic tool related to the fault:
| • | Combustion Signal cyl 1+3 |
| (See also description of readings/activations in diagnostic tool) |