T8 / P2535 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: None
+15 voltage too high or internal fault in the voltage measuring circuit

Fault symptom
None
On-board diagnosis
Type of diagnosis:
Enable criteria:
| Crankshaft stationary or rotating. |
Fault criteria:
| When input voltage exceeds 25.5 V. |
Dependent:
System reaction to a fault:
OK report:
| Fault criteria NOT fulfilled for 2 s with engine running. |
Fault handling:
| Type III without Check Engine. |
| (See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| System voltage too high or fault on the internal voltage measuring circuit. |
Functions in the diagnostic tool related to the fault:
| All read values under the "Start" group. |
| (See also description of readings/activations in diagnostic tool) |