Control module connections, auxiliary heater
 
  
 
 
  
   
    
     |  | Control module connections, auxiliary heater | 
   
  
  
   
   
   
   
    
    
    
     
      
      
      
      
      
      
      
      
     
     
      
       | Pin No. | Cable colour | Component/function | In/out | Test conditions | Across | Test reading | See | 
      
       | 1 | BU | Flame detector | In | . |  |  |   | 
      
       | 2 | BK | Flame detector | In | . |  |  |  | 
      
       | 3 | BU | Coolant temperature sensor 1 | In | . |  |  |   | 
      
       | 4 | BU | Coolant temperature sensor 1 | In | . |  |  |  | 
      
       | 5 | RD | Overheating protection | In | . |  |  |   | 
      
       | 6 | WH | Overheating protection | In | . |  |  |  | 
      
       | 7 |  | No connection |  | . |  |  |  | 
      
       | 8 |  | No connection |  | . |  |  |  | 
      
       | 9 | WH | Glow plugs | Out | . |  |  |   | 
      
       | 10 |  | No connection |  | . |  |  |  | 
      
       | 11 |  | No connection |  | . |  |  |  | 
      
       | 12 | BN | Glow plugs | Out | . |  |  |  | 
      
       | 13 | BK | Blower fan | Out | . |  |  |   | 
      
       | 14 | BN | Blower fan | Out | . |  |  |  |