| MID | TID | Unit/scale | Fault Code supported | Data | Min value | Max value | 
      
       | O2 sensor, B1S1 | 
      
       | $01 | $83 | 05 |  | Dynamic value calculated | 0.300 | 1.999 | 
      
       | O2 sensor, B1S2 | 
      
       | $02 | $01 | 0A |  | Minimum sensor voltage | 0.601 | 0.601 | 
      
       |  | $02 | 0A |  | Lean to rich threshold voltage | 0.601 | 0.601 | 
      
       |  | $07 | 0A |  | Minimum sensor voltage | 0 | 0.450 | 
      
       |  | $08 | 0A |  | Maximum sensor voltage | 0.450 | 1.079 | 
      
       |  | $81 | 0A |  | Minimum sensor voltage of oscillation check | 0 | 0.601 | 
      
       |  | $82 | 0A |  | Maximum sensor voltage of oscillation check | 0.601 | 1.079 | 
      
       |  | $83 | 0A |  | Offset voltage downstream pre catalyst | 0 | 0.201 | 
      
       | Catalyst monitor | 
      
       | $21 | $81 | 01 | P0420 | Catalyst monitor, evaluated value | 4096 | 65535 | 
      
       | EVAP monitor, cap off | 
      
       | $39 | $80 | 81 | P0455 | EVAP, monitor Cap off | -32768 | -1770 | 
      
       | EVAP monitor, 0,020" | 
      
       | $3C | $83 | 05 | P0456 | EVAP monitor leak factor. | 0 | 0 | 
      
       | EVAP monitor, 0,020" | 
      
       | $3C | $83 | 01 | P0456 | EVAP monitor leak factor. | 0 to 65535 counts | 1 count/bit | 
      
       | The same value is reported in MID:s 39 and 3C. When a large leak is present, all CID:s will show "Fail". | 
      
       |  | 
      
       | 3D | $8C | 81 |  | Tank pressure after purge valve is closed. | -8602 | 32767 | 
      
       |  | $88 | 81 |  | Tank pressure to detect stucked purge valve. | -32768 | -6 | 
      
       | O2 sensor,heater monitor B1S1 | 
      
       | 41 | $85 | 16 |  | Heater power | 714.9 | 1262.8 | 
      
       | O2 sensor,heater monitor B1S2 | 
      
       | 42 | $81 | 14 |  | Resistance of ceramic | N/A | 756 | 
      
       | AIR monitor | 
      
       | $71 | $80 | 05 |  | SAI air flow value | 0.750 | 1.999 | 
      
       | Fuel System Monitor Bank 1 | 
      
       | $81 | $80 | AF |  | Additive correction factor | -5.25 | +5.25 | 
      
       |  | $82 | 05 |  | Multiplicative correction factor | 0.825 | 1.174 | 
      
       | Misfire Monitor | 
      
       | $A2 | $0B | 24 | P0300/P0301 | EWMA misfire counts, cylinder 1 | 0 | 65535 | 
      
       |  | $0C | 24 | P0300/P0301 | DCY misfire counts, cylinder 1 | 0 | 65535 | 
      
       | $A3 | $0B | 24 | P0300/P0302 | EWMA misfire counts, cylinder 2 | 0 | 65535 | 
      
       |  | $0C | 24 | P0300/P0302 | DCY misfire counts, cylinder 2 | 0 | 65535 | 
      
       | $A4 | $0B | 24 | P0300/P0303 | EWMA misfire counts, cylinder 3 | 0 | 65535 | 
      
       |  | $0C | 24 | P0300/P0303 | DCY misfire counts, cylinder 3 | 0 | 65535 | 
      
       | $A5 | $0B | 24 | P0300/P0304 | EWMA misfire counts, cylinder 4 | 0 | 65535 | 
      
       |  | $0C | 24 | P0300/P0304 | DCY misfire counts, cylinder 4 | 0 | 65535 | 
      
       | $A6 | $0B | 24 | P0300/P0305 | EWMA misfire counts, cylinder 5 | 0 | 65535 | 
      
       | $A7 | $0B | 24 | P0300/P0305 | DCY misfire counts, cylinder 5 | 0 | 65535 | 
      
       |  | $0B | 24 | P0300/P0306 | EWMA misfire counts, cylinder 6 | 0 | 65535 | 
      
       |  | $0C | 24 | P0300/P0306 | DCY misfire counts,cylinder 6 | 0 | 65535 |