Wiring harness valve housing with temperature sensor Z19DTH
| Wiring harness valve housing with temperature sensor Z19DTH | 
| To remove | 
| 1. | Remove
        
         Valve housing cover Z19DTH
        
        . | |
| 2. | Remove
        
         Valve housing Z19DTH | |
| 3. | Remove the control module. | |
| • | Unplug the connector   | 
| • | Set the gear selector lever in position P and remove the nut (A) for the lever (B).   | 
| • | Engage position N and remove the lever. | 
| • | Pull the gear cable sleeve (C) backwards and lift up the cable and move it aside. | 
| • | Remove the control module screws x 3 (D). | 
| • | Lift the control module off the shaft and connector. Lift straight up to avoid damaging the connector on the gearbox. | 
| 4. | Remove the wiring harness. | |
| • | Remove the circlip (A).   | 
| • | Lift out the wiring harness (B). | 
| To fit | 
| 1. | Fit the wiring harness. | |
| • | Fit a new seal (B) in the gearcase and an O-ring on the connection (A).   | 
| 2. | Fit in the wiring harness (B).   | |
| • | Make sure that the connector's guide pin locates in the groove and fit the circlip (A). | 
| 3. | Fit the control module. 
 | ||||||||||
| • | Carefully press the control module straight and down towards the shaft and the connector. | 
| • | Fit the control module screws (D). Tightening torque: 25 Nm (18 lbf ft)   | 
| • | Pull the gear cable sleeve (C) backwards and fit the cable in its bracket. | 
| • | Fit the lever (B). | 
| • | Engage position P and fit the nut (A). Tightening torque: 15 Nm (11 lbf ft) | 
| • | Engage position N. | 
| • | Plug in the connector. | 
| 4. | Fit
        
         Valve housing Z19DTH | |
| 5. | Fit
        
         Valve housing cover Z19DTH
        
        . | |

 
		