EDC16 / P0180 07
Read the instructions below then start the fault diagnostic procedure.
| P0180 07 |
Fuel Temperature Sensor Circuit. Open Circuit/Short to B+.
On-board diagnosis
Fault criteria:
| Input voltage is higher than 4.96 V for more than 0.6 s. |
System reaction to a fault:
| Control module uses 50 degrees C as substitute value. |
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. |