RDCM / C0574 13
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Message appears in display.
ECU Temperature too High
Fault symptom
Message appears in display.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
The control module temperature has exceeded 115°C for more than 3 s. |
System reaction to a fault:
Rear wheel drive shut down |
Diagnostic help
Diagnosis regards:
Electrical fault in the component. |
Functions in the diagnostic tool related to the fault:
See menu "All - Add/Remove" |
(See also description of readings/activations in diagnostic tool) |