Bypass valve check, B207E/L
Bypass valve check, B207E/L |
Checks |
1. |
Detach the vacuum hose from the bypass valve.
|
2. |
Connect pressure/vacuum pump (30 14 883 Pressure/vacuum pump) and generate vacuum pressure in the valve.
|
3. |
Check that the diaphragm is intact. If the diaphragm is damaged, the vacuum is relieved.
|
4. |
Pump up an overpressure in the valve.
|
5. |
Check that the diaphragm is intact. If the diaphragm is damaged, the overpressure is relieved.
|
6. |
Detach the pump.
|
7. |
Connect the vacuum hose.
|