ME9 / P0238 00
Read the instructions below then start the fault diagnostic procedure.
Symptom: Malfunction Indicator Lamp
| P0238 00 |
Fault symptom
Malfunction Indicator LampOn-board diagnosis
Type of diagnosis:
| Continuous |
Enable criteria:
| Battery voltage must be between 10 - 18 V. |
| NONE of the following DTCs must be detected: |
| P2228, P2229 |
Fault criteria:
| When the signal on the control module input corresponds to pressure greater than 300 Pa for more than 2 seconds. |
OK report:
| Fault criteria NOT fulfilled. |
Fault handling:
| Type III |
| (See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
| Test value: |
| Absolute pressure sensor, charge air |
| (See also description of readings/activations in diagnostic tool) |