STC / B1310 59
Read the instructions below then
start the fault diagnostic procedure.
Symptom: The soft top stops somewhere in its cycle.
Message appears in display.
Soft Top Closed, Position Sensor, Timeout
![](/images/9-3-9440/img-im/img7186.jpg)
Fault symptom
The soft top stops somewhere in its cycle.
Message appears in display.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Soft top opening/closing activated |
Fault criteria:
The position sensor assumes impermissible position while soft top is in operation |
Diagnostic help
Diagnosis regards:
Check that the bow is locked within the specified time |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |