Wiring harness valve housing with temperature sensor B207
| Wiring harness valve housing with temperature sensor B207 |
| To remove |
| 1. |
Remove the
Valve housing cover, B207
|
|
| 2. |
Remove the
Valve housing, B207
.
|
|
| 3. |
Remove the control module.
|
|
| • |
Unplug the connector
|
| • |
Set the gear selector lever in position P and remove the nut (A) for the lever (B).
|
| • |
Engage position N and remove the lever.
|
| • |
Pull the gear cable sleeve (C) backwards and lift up the cable and move it aside.
|
| • |
Remove the control module screws x 3 (D).
|
| • |
Lift the control module off the shaft and connector. Lift straight up to avoid damaging the connector on the gearbox.
|
| 4. |
Remove the wiring harness.
|
|
| • |
Remove the circlip (A).
|
| • |
Lift out the wiring harness (B).
|
| To fit |
| 1. |
Fit the wiring harness.
|
|
| • |
Fit a new seal (B) in the gearcase and an O-ring on the connection (A).
|
| 2. |
Fit in the wiring harness (B).
|
|
| • |
Make sure that the connector's guide pin locates in the groove and fit the circlip (A).
|
| 3. |
Fit the control module.
|
||||||||||
| • |
Carefully press the control module straight and down towards the shaft and the connector.
|
| • |
Fit the control module screws (D).
Tightening torque 25 Nm (18 lbf ft)
|
| • |
Pull the gear cable sleeve (C) backwards and fit the cable in its bracket.
|
| • |
Fit the lever (B).
|
| • |
Engage position P and fit the nut (A).
Tightening torque 15 Nm (11 lbf ft) |
| • |
Engage position N.
|
| • |
Plug in the connector.
|
| 4. |
Fit the
Valve housing, B207
.
|
|
| 5. |
Fit the
Valve housing cover, B207
.
|
|