Test readings, SRM
| Test readings, SRM |
The following pages contain directions and readings for testing the control module.
| Remember: |
| • |
Observe the test criteria. Use common sense when assessing the test results.
|
|
| • |
The test readings presented here are with the ignition ON unless stated otherwise.
|
|
| • |
Check these points:
|
|
| - |
Check first that the control module is receiving power and is grounded.
|
| - |
Then check all sensor inputs and signals from other systems.
|
| - |
Finally, check the control module outputs. Remember that the test readings are not a confirmation of whether the actuator is in working order.
|
| • |
If a test reading is incorrect, use the wiring diagram to locate the leads, connectors or components that need to be checked further.
|
|
| • |
Specified test readings are for a calibrated Fluke 88/97.
|
|
| • |
Test values show the signal pulse ratio and pulse width respectively. A scan tool with pulse ratio and pulse width measurement respectively must be used.
|
|
| Note | ||
|
All units on the I and P buses send signals. |
| 12-pin connector |
| Number of connection pins | 12 |
| Pin | Component/function | In/out | Test criteria | Measure across | Test reading |
| 1 | Instrument bus | 1 and B- | The test lamp should flash | ||
| 2 | Logic ground | ||||
| 3 | High position button | 3 and 6 | 4.5 volt | ||
| 4 | Position button low | 4 and 6 | 4.5 volt | ||
| 5 | +30 | 5 and 6 | B+ | ||
| 6 | Ground | 5 and 6 | B+ | ||
| 7-12 | No connection |