ME9 / P0459 00
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Malfunction Indicator Lamp
	
EVAP Purge Valve Circuit, Short to B+

Fault symptom
Malfunction Indicator Lamp
On-board diagnosis
Type of diagnosis:
Enable criteria:
| Battery voltage must be between 10 - 18 V. | 
| EVAP valve activated/deactivated once. | 
Fault criteria:
| When output voltage is more than 4.6 V when the output is active. | 
OK report:
| When the PWM signal on the output is between 2% and 80%. | 
Fault handling:
| (See section Fault handling III, "Other emission-related components and functions" for more information.) | 
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. | 
Functions in the diagnostic tool related to the fault:
| (See also description of readings/activations in diagnostic tool) |