SAAB WIS ONLINE

RDCM / C0406 0B

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display.

  C0406 0B


Differential Clutch Solenoid Valve/Hydraulic Pumpmotor Circuit, Current above Threshold

Fault symptom

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Current strength on output exceeds 11A

System reaction to a fault:

Rear wheel drive shut down

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or components.

Functions in the diagnostic tool related to the fault:

Test value:
Pump Motor Amps
Rear Wheel Drive Solenoid Amps
Activation:
Pump Motor
Rear Wheel Drive Solenoid Amps
(See also description of readings/activations in diagnostic tool)