T8 / P0139 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
O2S Circuit, Slow Response Sensor 2
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
On-board diagnosis
Type of diagnosis:
Enable criteria:
Coolant temperature must be over 60°C. |
Battery voltage must be between 11 - 16 V. |
Catalytic converter diagnosis active |
Diagnostics for the following components/systems must NOT have reported a fault: |
• | Shut-off valve, EVAP canister. |
• | Tank integrity system (EVAP). |
Fault criteria:
Too long a time until O2S2 shows lean. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
The diagnosis runs at the end of the catalytic converter diagnosis (P0420). |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |