SAAB WIS ONLINE

Test readings, BCM

Test readings, BCM

Scope



The following pages contain values and instructions for measuring signals and levels on BCM.

Remember:


Note the test conditions and use common sense when assessing the test results.

First check that the control module has a power supply and is grounded.

Then check all sensor inputs and signals from other systems.

Finally, check the control module outputs. Remember that the test reading does not indicate whether the actuator works.

If any reading is not OK, consult the wiring diagram to trace which leads, connectors or components should be checked more thoroughly.

The specified values refer to a calibrated Fluke 88/97.

Test readings % (+) and ms (+) show the signal's pulse ratio and pulse length, respectively. A test instrument that can measure pulse ratio and pulse width must be used. The sign indicates the positive trigger pulse, TRIG+.


Connection K78


Note

All units connected to the I and P-buses send out signals.


Control module pin Component/ function IN/OUT Test conditions Across Test reading
1 Ultrasound sensor, signal IN Ignition ON 1-6 B+
2 Seat sensor, signal IN Ignition ON Unoccupied seat Occupied seat 2-6 2-6 5V Approx. 1V
3 Electrically heated rear window, indicator OUT Ignition ON Electrically heated rear window ON 3-6 B+
4 Seat sensor, ground IN Ignition ON 4-B+ B+
5 LED, alarm OUT Ignition ON Activate with T2 5-6 8V for 5 secs.
6 Power ground IN Ignition ON 6-B- <0.1V
7 Rear fog light OUT Ignition ON 7-6 B+
8 Not connected IN
9 Door switch RR IN Ignition ON Open door Closed door 9-21 9-21 4.1V 7.3V
10 Door switch RL IN Ignition ON Open door Closed door 10-21 10-21 4.1V 7.3V
11 Door switch FR IN Ignition ON Open door Closed door 11-21 11-21 4.1V 7.3V
12 Door switch FL IN Ignition ON Open door Closed door 12-21 12-21 4.1V 7.3V
13 Coolant level switch, IN Open switch Closed switch 13-21 13-21 B+ <0.1V
14 Instrument illumination, bulbs OUT Ignition ON Rheostat MAX Rheostat MIN 14-21 14-21 B+ 1.6V
15 Not connected
16 Instrument illumination, LED OUT Ignition ON Rheostat MAX Rheostat MIN 16-21 16-21 B+ 3.3V
17 Indicator, hazard warning lights OUT Ignition ON Hazard warning lights ON 17-21 B+/0V
18 Interior lighting PWM OUT Ignition ON 18-21 <0.5
19 Interior lighting OUT Ignition ON 19-21 B+
20 Solenoid, fuel filler flap IN/OUT Ignition ON Hazard warning lights ON 20-21 B+ for 0.5 s
21 Power ground IN Ignition ON 21-B- <0.1V
22-27 Not connected
28 Front fog lights OUT Ignition ON 28-21 6V
29 Headlamps pos 1 OUT Ignition ON 29-21 6V
30 Headlamps pos 2 OUT Ignition ON 30-21 5.5V
31 Not connected
32 Luggage compartment switch IN Ignition ON Open boot lid Closed boot lid 32-21 32-21 4.1V 7.3V
33 Not connected
34 Brake fluid level switch IN Ignition ON Open switch Closed switch 34-21 34-21 B+ <0.1
35 AC OUT Ignition ON Button not actuated Button depressed 35-21 35-21 B+ <0.5
36-39 Not connected
40 I-bus IN/OUT Ignition ON Connect 86 11 857 Test lamp, red/green 40-21 The test lamp should flash
41 I-bus IN/OUT Connect 86 11 857 Test lamp, red/green ON 4-21 The test lamp should flash
42-43 Not connected
44 Outside temperature sensor IN Ignition ON 44-B+ B+
45 Siren OUT Ignition ON 45-21 B+
46 Not connected
47 Outside temperature sensor Ignition ON 20 degrees Sensor disconnected 47-21 47-21 2.2V 5V
48-50 Not connected
51 Parking heater OUT Ignition ON Relay activated 51-21 <0.5V
52 Not connected
53 Block heater OUT Ignition ON Output active (heater on) 53-21 approx. B+
54 Not connected
55 Handbrake switch IN Ignition ON Handbrake applied Handbrake not applied 55-21 55-21 <0.1 B+
56 Not connected
57 Electrically heated rear window OUT Ignition ON 57-21 B+
58 Boot lid lock microswitch IN Ignition ON ON Unactuated handle Depressed handle 58-21 58-21 10V <0.5V
59 Not connected
60 Bonnet switch IN Ignition ON Open bonnet Closed bonnet 60-21 60-21 <0.5V 10V
61 Hazard warning lights OUT Ignition ON 61-21 B+
62 Ultrasound sensor, ground IN Always 62-B+ B+
63-77 Not connected
78 Solenoid, fuel filler flap IN/OUT Ignition ON 78-21 B+ for 0.5 s


(*) All connected control modules send out voltage.

Connection K16

Note

All units connected to the I and P-buses send out signals.


Control module pin Component/ function IN/OUT Test conditions Across Test reading
1-4 Not connected OUT
5 +30 IN Ignition ON 5-B+ <0.5
6 +54 OUT Ignition ON 6-B+ <0.5
7 Not connected
8 Interior lighting relay OUT 8-B+ <0.5
9-12 Not connected
13 Accessories relay OUT Ignition ON 13-B+ <0.5
14 Not connected
15 Interior lighting IN 15-B+ <0.5
16 +30 IN 16-B+ <0.5