Defrost air distribution flap stepping motor
Defrost air distribution flap stepping motor |
To remove |
1. |
Dismantle the
driver's acoustic insulation
.
|
2. |
Dismantle the air duct for the floor vent.
The defrost air distribution flap stepping motor is located at the top front on the heating and ventilation unit's left hand side. |
3. |
Remove the screws from the stepping motor.
|
4. |
Carefully lift out the stepping motor a little. Turn the stepping motor so that it releases from the link arm.
|
5. |
Dismantle the stepping motor's connector by pressing in the lock and pulling out the connector.
|
To fit |
1. |
Connect the connector to the stepping motor. Make sure the connector locks correctly.
|
2. |
Fit the stepping motor to the link arm and align the steeping motor on the guide pin.
|
3. |
Fit the stepping motor.
|
4. |
Fit the air duct for the floor vent.
|
5. |
Fit the
driver's acoustic insulation
.
|